Overview
They are automatic “Class N” autoclaves as same shape as ICANCLAVE D, but with non-vacuum. An independent steam generator was built-in, worked by dynamic pulsed air removal for uniform temperature and full steam distribution.
Excellent Performance
- Full automatic table top autoclave with pre-set programs.
- Worked non- vacuum
- In built independent rapid steam generator ensures quick sterilization cycles.
- Rapid post sterilization vacuum drying.
- With one flash water tank and used one water tank.
- LCD screen displaying time, temperature and pressure, process alert and instrument
- User friendly interface.
- Self-initialization when work in different altitude.
- Multilanguage menu: Chinese, English, Spanish, German, Lithuanian, Polish, French, Czech, Hungarian, Romanian, Dutch, Latvian, Italian, Portuguese, Russian, Croatian.
Safety and Monitoring
- Double safety protection system prevents the cycle from starting if the door is not correctly locked.
- This system also prevents the door from opening if the pressure inside the chamber is not equal to atmospheric pressure outside the chamber.
- Pressure safety valve prevents over pressure in the chamber and steam generator.
- The power is automatically cut if a short circuit or electrical fault occurs.
- Able to detect and identify the exact cause of any problem, and to issue a specific error code to the operator.
- Water level main switch in the main tank controlling the min and max water level.
- Automatic warning for maintenance.
Documentation
- Printer (option): an external printer is optional for all “icanclave”D autoclaves.
- USB port: it is used for connecting a USB stick, all sterilization data are automatically written in the USB stick, and can be ready directly in any PC and stored electronically.
- Internal Memory: the last 20 cycles can be automatically stored in the autoclave system, which can be printed out at any time.
Order Code | ICANCLAVE K208 | ICANCLAVE K212 | ICANCLAVE K218 | ICANCLAVE K223 |
---|---|---|---|---|
Model Number | STE-8-D | STE-12-D | STE-18-D | STE-23-D |
Chamber Dimension | Ø170×320 mm | Ø200×360 mm | Ø247×350 mm | Ø247×450 mm |
Chamber Volume | 8 L | 12 L | 18 L | 23 L |
Number of Trays | 2/ Max. 3 | 2/ Max. 3 | 3/ Max. 4 | 3/ Max. 4 |
Tray size | 130×265 mm | 156×295 mm | 192×285 mm | 192×380 mm |
Voltage, Freq. | 220/110V, 50/60Hz | 220/110V, 50/60Hz | 220/110v, 50/60Hz | 220/110v, 50/60Hz |
Power | 1900 w | 1900 w | 1900 w | 2100 w |
Overall Dimension (WxHxD) | 420x370x525 mm | 420x370x595 mm | 490x455x600 mm | 490x455x690 mm |
Weight | 35 kgs | 38 kgs | 45 kgs | 50 kgs |
Program | Temp. (°C) | Pressure (Mpa) | Sterilization time (min.) |
---|---|---|---|
SOLID | 134 | 210 | 4 |
121 | 110 | 20 | |
LIQUID | 134 | 210 | 10 |
121 | 110 | 30 | |
WRAPPED | 134 | 210 | 10 |
121 | 110 | 30 | |
TEXTILE | 134 | 210 | 10 |
121 | 110 | 30 | |
PRION | 134 | 210 | 18 |
DRYING | – | – | – |
- 93/42/EEC Directive on Medical Devices.
- 97/23/EEC Directive on Pressure Equipment.
- EN 13060 Small Steam Sterilizers.
- EN 61326, EN 61000 Electromagnetic Compatibility.
- EN 61010-1, UL 61010-1Safety requirements.
- EN 61010-2-040, IEC 61010-2-040. Specific requirements for steam sterilizers used for treatment of medical materials.