ClaveMed 18T Pro and 23T Pro are ClaveMed autoclaves with innovation technologies design in Europe, they have chamber volume of appr.18L and 23L, mainly used in private specialized hospitals and small public hospitals for the fast sterilization of small instruments such as ophthalmology and surgery.
- Standard pre-programmed cycles: Quick S, Standard B, Soft B, Prion 134℃, B&D Test, Helix Test, Vacuum Test.
- Other cycles: Delay start (reserve the cycle). Descale (cleaning steam generator and tube).
- Steam generator: Built-in steam generator with 2000W rated power.
- Water Reservoir: One distilled water reservoir 4L and one wastewater reservoir.
- Door system: Vacuum-assisted electronic motorized door system.
- Water Quality monitoring: Cycle is not available to start if the water quality worse than the value be set.
- Color touch screen: Displaying for cycle process, time, temperature, pressure, process alert messages, error codes, and all detail information.
- User friendly interface: Easy to operate.
- Warning system: Warning of not enough water in distiller water reservoir. Warning of wastewater tank be full. Warning of bad quality water. Warning of door unlock. Warning of printer out of paper.
- Atmospheric pressure identification system: It can automatically identify the local atmospheric pressure.
- Safety system: Over pressure safety valve. Over temperature switch. Safety lock system preventing improper door lock. Circuit breakers protecting the machine when it has short-circuited or over current. Automatic warning for maintenance.
- Extra functions: Option to be connected directly with Water Demineralizer Listo-23.
Printer: an internal printer print the cycle report automatically.
USB port: it is used for connecting a USB disc, all sterilization data are automatically output in the USB disc and can be ready directly in any PC and stored electronically.
Internal Memory: the last 9999 cycles can be automatically stored in the autoclave system, which can be printed out at any time.
Barcode label printer port: it is used for connecting an optional barcode printer prints barcode labels that contain the information related to the sterilization cycle.
Order Code | ClaveMed 18T Pro | ClaveMed 23T Pro |
---|---|---|
Model Number | STE-18-T Pro | STE-23-T Pro |
Chamber Dimension | Φ250x320mm | Φ250x450mm |
Chamber Volume | appr.18L | appr.23L |
Number of Trays | 5 | 5 |
Material of Trays | Aluminum | Aluminum |
Size of Trays (WxH) | 192x285mm | 192x380mm |
Voltage. Freq. | 220/110V, 50/60Hz | 220/110V, 50/60Hz |
Power | 2300W | 2300W |
Overall Dimension (WxHxD) | 490x455x600 mm | 490x455x690 mm |
Weight | 95kgs | 103kgs |
Program | Temp./Pressure | Steri. Time | Total Time (min) | |
---|---|---|---|---|
18T Pro | 23T Pro | |||
Quick S | 134℃/210Kpa | 4 min | 11-15 | 15-20 |
Standard B | 134℃/210Kpa | 4 min | 30-49 | 38-57 |
Soft B | 121℃/110Kpa | 20 min | 38-54 | 46-62 |
PRION 134 | 134℃/210Kpa | 18 min | 37-52 | 45-60 |
B&D TEST | 134℃/210Kpa | 3.5 min | 28-35 | 28-35 |
HELIX TEST | 134℃/210Kpa | 3.5 min | 28-35 | 28-35 |
VACUUM TEST | – | – | 20-25 | 20-25 |
* The cycle time is based on different loading and with/without pre-heating.
* Sterilization time and Drying time can be adjusted.
93/42/EEC Directive on Medical Devices.
Pressure Equipment Directive 2014/68/EU.
EN 13060 Small Steam Sterilizers.
EN 61326, EN 61000 Electromagnetic Compatibility.
EN 61010-1, UL 61010-1Safety requirements.
EN 61010-2-040, IEC 61010-2-040.