ClaveLab

2545D

ClaveLab 2545D is a safe and accurate sterilizers mainly designed for laboratories, scientific research institutions and colleges sterilization of solid instruments, liquid, culture medium, waste, etc.

  • User- defined programmed cycles: Sterilization temperature, pulsating vacuum times, sterilization time and drying time can be user-defined, not only to meet the sterilization of instruments, glasses, liquids, culture media, etc., but also to maintain the temperature after sterilizing process.

  • Steam generator: Built-in steam generator with 1500W rated power.

  • Water Reservoir: One distilled water reservoir 2.5L and one wastewater reservoir.

  • Door system: Manual door system.

  • Media temperature sensor: Equipped with a special media temperature sensor for liquid sterilization. The media sensor is inserted into the liquid to monitor the temperature of the liquid accurately and effectively, to achieve effective sterilization.

  • LCD Display: Displaying for cycle process, time, temperature, pressure, process alert and error codes. 

  • User friendly interface: Easy to operate.

  • Warning system: Warning of not enough water in distiller water reservoir. Warning of wastewater tank be full. Warning of door unlock. Warning of printer out of paper.

  • Atmospheric pressure identification system: It can automatically identify the local atmospheric pressure.

  • Safety system: Over pressure safety valve. Over temperature switch.  Safety lock system preventing improper door lock. Circuit breakers protecting the machine when it has short-circuited or over current. Automatic warning for maintenance.

  • Extra functions: Option to be connected directly with Water Demineralizer Listo-23.

  • Internal printer: it prints the cycle report automatically.

  • USB port: it is used for connecting a USB disc, all sterilization data are automatically output in the USB disc and can be ready directly in any PC and stored electronically.

  • Internal Memory: the last 10000+ cycles can be automatically stored in the autoclave system, which can be printed out at any time.

Order CodeClaveMed 2545D
Model Number2545D
Chamber DimensionØ 250x450mm
Chamber Volumeappr. 23L
Material of TraysAluminum
Voltage. Freq.220/110V, 50/60Hz
Power1750W
Overall Dimension (WxHxD)490x455x690 mm
Weight53kg
Program Vacuum times Steri.Temp. / Time Drying Temp./ Time
Liquid 1 0-1 105℃-134℃/ 1-99min 45℃-60℃/ 0-30min
Liquid 2 0-1 105℃-134℃/ 1-99min 45℃-60℃/ 0-30min
Instruments 1 1-3 105℃-134℃/ 1-99min 45℃-60℃/ 0-30min
Instruments 2 1-3 105℃-134℃/ 1-99min 45℃-60℃/ 0-30min
Waste 1 1-3 105℃-134℃/ 1-99min 45℃-60℃/ 0-30min
Waste 2 1-3 105℃-134℃/ 1-99min 45℃-60℃/ 0-30min
Agar 0-1 105℃-134℃/ 1-99min 45℃-60℃/ 0-30min
Dry 0 / no limited
B&D/Helix Test 3 3.5min 15min
Vacuum Test 3 3.5min /
  • 93/42/EEC Directive on Medical Devices.

  • Pressure Equipment Directive 2014/68/EU.

  • EN 13060 Small Steam Sterilizers.

  • EN 61326, EN 61000 Electromagnetic Compatibility.

  • EN 61010-1, UL 61010-1Safety requirements.

  • EN 61010-2-040, IEC 61010-2-040.

  • RoHS Directive 2011/65/EU.